STAT: The number of annual deaths from ESD in the U.S. are unknown, since they are counted among all drownings. But anecdotal evidence shows that ESD is widespread. ESD prevention groups have successfully urged some states to enact safety standards, including the installation of ground-fault circuit interrupters and a central shutoff for a dock's electrical system.
Ultraviolet light (UV) is very effective at inactivating cysts, in low turbidity water. UV light's disinfection effectiveness decreases as turbidity increases, a result of the absorption, scattering, and shadowing caused by the suspended solids. The main disadvantage to the use of UV radiation is that, like ozone treatment, it leaves no residual disinfectant in the water; therefore, it is sometimes necessary to add a residual disinfectant after the primary disinfection process. This is often done through the addition of chloramines, discussed above as a primary disinfectant. When used in this manner, chloramines provide an effective residual disinfectant with very few of the negative effects of chlorination.
Energy-recovery pump: a reciprocating piston pump having the pressurized concentrate flow applied to one side of each piston to help drive the membrane feed flow from the opposite side. These are the simplest energy recovery devices to apply, combining the high pressure pump and energy recovery in a single self-regulating unit. These are widely used on smaller low-energy systems. They are capable of 3 kWh/m3 or less energy consumption.
The motorized blade isn't always the most dangerous thing about using a chain saw. Trees contain enormous amounts of energy that can release in ways both surprising and lethal. If a tree stands at an angle, it becomes top-heavy and transfers energy lower in the trunk. When sawed, it can shatter midcut and create a so-called barber chair. The fibers split vertically, and the rearward half pivots backward. "It's very violent and it's very quick," says Mark Chisholm, chief executive of New Jersey Arborists.
Energy-recovery pump: a reciprocating piston pump having the pressurized concentrate flow applied to one side of each piston to help drive the membrane feed flow from the opposite side. These are the simplest energy recovery devices to apply, combining the high pressure pump and energy recovery in a single self-regulating unit. These are widely used on smaller low-energy systems. They are capable of 3 kWh/m3 or less energy consumption.
The simplest levels of filtration can be achieved by running the water through a cloth. The tighter the weave of the cloth the better it will filter water, as it will be able to capture smaller/finer particles. Just about any cloth will catch the “big” stuff. Folding the cloth to form multiple layers will help in this process. If you are setting up a long term camp, you can set up a more intricate filtration system, that will not only filter particulates, but also improve taste.

Only a part of the saline feed water pumped into the membrane assembly passes through the membrane with the salt removed. The remaining "concentrate" flow passes along the saline side of the membrane to flush away the concentrated salt solution. The percentage of desalinated water produced versus the saline water feed flow is known as the "recovery ratio". This varies with the salinity of the feed water and the system design parameters: typically 20% for small seawater systems, 40% – 50% for larger seawater systems, and 80% – 85% for brackish water. The concentrate flow is at typically only 3 bar / 50 psi less than the feed pressure, and thus still carries much of the high-pressure pump input energy.
Waters exiting the flocculation basin may enter the sedimentation basin, also called a clarifier or settling basin. It is a large tank with low water velocities, allowing floc to settle to the bottom. The sedimentation basin is best located close to the flocculation basin so the transit between the two processes does not permit settlement or floc break up. Sedimentation basins may be rectangular, where water flows from end to end, or circular where flow is from the centre outward. Sedimentation basin outflow is typically over a weir so only a thin top layer of water—that furthest from the sludge—exits.
If the right equipment is available distillation is another way to ensure removal of bacteria and viruses. This is one method that will allow us to use salt water for drinking. Note: If you own a boat and use it for off shore trips a desalinator such as the Katadyn Survivor series would be a prudent purchase. The Katadyn Survivor 40E can be operated manually or using 12/24 V DC power. We will cover makeshift ways of distillation in future articles.
The pore size of the filter, usually measured in microns, will determine what will be filtered through. While a standard micron size of 0.2 is small enough to block heavy metals such as lead and copper and large parasites such as Cryptosporidium, it will not block viruses. The National Sanitation Foundation sets a standard for effective water filtration products so look for an NSF stamp when selecting a filter to purchase.
I'm Jeremiah Castelo, the owner of World Water Reserve. I'm a writer and researcher with a particular interest in sustainability and rural living, water scarcity, and innovative water purification methods. I utilize my multimedia and communication experience in the NGO and humanitarian fields to bring light to important topics. My passion is to educate others on the reality of the global water crisis and on ways to sustain themselves and their families in the midst of it.
In 1904, Allen Hazen showed that the efficiency of a sedimentation process was a function of the particle settling velocity, the flow through the tank and the surface area of tank. Sedimentation tanks are typically designed within a range of overflow rates of 0.5 to 1.0 gallons per minute per square foot (or 1.25 to 2.5 litres per square meter per hour). In general, sedimentation basin efficiency is not a function of detention time or depth of the basin. Although, basin depth must be sufficient so that water currents do not disturb the sludge and settled particle interactions are promoted. As particle concentrations in the settled water increase near the sludge surface on the bottom of the tank, settling velocities can increase due to collisions and agglomeration of particles. Typical detention times for sedimentation vary from 1.5 to 4 hours and basin depths vary from 10 to 15 feet (3 to 4.5 meters).[6]:9.39–9.40[7]:790–1[8]:140–2, 171 
×