Pure water has a pH close to 7 (neither alkaline nor acidic). Sea water can have pH values that range from 7.5 to 8.4 (moderately alkaline). Fresh water can have widely ranging pH values depending on the geology of the drainage basin or aquifer and the influence of contaminant inputs (acid rain). If the water is acidic (lower than 7), lime, soda ash, or sodium hydroxide can be added to raise the pH during water purification processes. Lime addition increases the calcium ion concentration, thus raising the water hardness. For highly acidic waters, forced draft degasifiers can be an effective way to raise the pH, by stripping dissolved carbon dioxide from the water.[4] Making the water alkaline helps coagulation and flocculation processes work effectively and also helps to minimize the risk of lead being dissolved from lead pipes and from lead solder in pipe fittings. Sufficient alkalinity also reduces the corrosiveness of water to iron pipes. Acid (carbonic acid, hydrochloric acid or sulfuric acid) may be added to alkaline waters in some circumstances to lower the pH. Alkaline water (above pH 7.0) does not necessarily mean that lead or copper from the plumbing system will not be dissolved into the water. The ability of water to precipitate calcium carbonate to protect metal surfaces and reduce the likelihood of toxic metals being dissolved in water is a function of pH, mineral content, temperature, alkalinity and calcium concentration.[5]
The pore size of the filter, usually measured in microns, will determine what will be filtered through. While a standard micron size of 0.2 is small enough to block heavy metals such as lead and copper and large parasites such as Cryptosporidium, it will not block viruses. The National Sanitation Foundation sets a standard for effective water filtration products so look for an NSF stamp when selecting a filter to purchase.
Reverse osmosis per its construction removes both harmful contaminants present in the water, as well as some desirable minerals. Modern studies on this matter have been quite shallow, citing lack of funding and interest in such study, as re-mineralization on the treatment plants today is done to prevent pipeline corrosion without going into human health aspect. They do, however link to older, more thorough studies that at one hand show some relation between long-term health effects and consumption of water low on calcium and magnesium, on the other confess that none of these older studies comply to modern standards of research [27]

All forms of chlorine are widely used, despite their respective drawbacks. One drawback is that chlorine from any source reacts with natural organic compounds in the water to form potentially harmful chemical by-products. These by-products, trihalomethanes (THMs) and haloacetic acids (HAAs), are both carcinogenic in large quantities and are regulated by the United States Environmental Protection Agency (EPA) and the Drinking Water Inspectorate in the UK. The formation of THMs and haloacetic acids may be minimized by effective removal of as many organics from the water as possible prior to chlorine addition. Although chlorine is effective in killing bacteria, it has limited effectiveness against pathogenic protozoa that form cysts in water such as Giardia lamblia and Cryptosporidium.
Advantage is that you are not adding any chemicals to your water, which takes out the guess work as far as dosage. The disadvantage, if it can even be called that, is that you have to have a source of heat(fire, stove, etc.) in order to bring the water to the boiling point. Also we have to remember that this does not remove chemical such as petroleum or pesticides which can be harmful as well.
One of the most frequent compliments of the Home Master Full Contact Reverse Osmosis Water Filter System is that it delivers great water pressure when compared to other reverse osmosis kits. This can be credited to the permeate pump along with the 3/8 inch dispenser tubing used in this system, which results in a faster flow of water than the typical ¼ inch tubing found on many other reverse osmosis systems.
This water filtration system has 7 stages of treatment, including an 11-watt UV light to zap any microorganisms that may be lurking in well water. While this isn’t usually a major concern for homeowners on municipal water, the conditions of a well sometimes harbor bacteria and microorganisms that could pass through your plumbing and into your glass. A UV sterilizer is an efficient, effective way to eliminate this risk and have more peace of mind when drinking well water.
Plumbosolvency reduction: In areas with naturally acidic waters of low conductivity (i.e. surface rainfall in upland mountains of igneous rocks), the water may be capable of dissolving lead from any lead pipes that it is carried in. The addition of small quantities of phosphate ion and increasing the pH slightly both assist in greatly reducing plumbo-solvency by creating insoluble lead salts on the inner surfaces of the pipes.
Advantage is that you are not adding any chemicals to your water, which takes out the guess work as far as dosage. The disadvantage, if it can even be called that, is that you have to have a source of heat(fire, stove, etc.) in order to bring the water to the boiling point. Also we have to remember that this does not remove chemical such as petroleum or pesticides which can be harmful as well.
That brings us to filtration by manufactured filters. These devices allow us to go into microfiltration and ultrafiltration. By simply running the water through these porous ceramic filters we can effectively remove bacteria and viruses depending on the quality of the filter and the pore size. See chart above. This is where high quality filters such as the Katadyn Combi Filter can filter down to 0.2-micron level capturing Giardia, Crypto, bacteria and most viruses. Some filters are chemically impregnated to ensure complete removal of bacteria. The information below will give more detail.
Household water treatment systems are composed of two categories: point-of-use and point-of-entryExternal (NSF). Point-of-entry systems are typically installed after the water meter and treat most of the water entering a residence. Point-of-use systems are systems that treat water in batches and deliver water to a tap, such as a kitchen or bathroom sink or an auxiliary faucet mounted next to a tap.
It’s extremely important to confirm your water has been purified or treated before drinking. If your water is contaminated and you don’t have bottled water, there are various water purification methods that are used today, and each method has its merits and demerits. Filtering is good for basic water tasks such as sediment and chlorine removal, but in the long run reverse osmosis is the best option. At Schultz Soft Water we focus on reverse osmosis units because they require a lot less energy and time required to make water versus distillation.
The tourist season got off to a grisly start this year in Gulf Shores, Ala. During a two-day period in early June, four men drowned after being caught in rip currents. The unusually strong currents were invisible, not even roiling the surface. Rip currents occur when water rushing back from the shoreline is channeled through a narrow gap between two sand bars, accelerating the outward flow.

In the production of bottled mineral water, the water passes through a reverse osmosis water processor to remove pollutants and microorganisms. In European countries, though, such processing of natural mineral water (as defined by a European directive[10]) is not allowed under European law. In practice, a fraction of the living bacteria can and do pass through reverse osmosis membranes through minor imperfections, or bypass the membrane entirely through tiny leaks in surrounding seals. Thus, complete reverse osmosis systems may include additional water treatment stages that use ultraviolet light or ozone to prevent microbiological contamination.
Like most under sink reverse osmosis systems, you’ll need to clear enough space for the 3.2-gallon pressurized storage tank and the filter cartridges. But once you do, you’ll find that the rest of the installation is easy according to most reviewers. One user mentions that they move every 3 years but are happy to uninstall and re-install the system in each new residence due to the high performance and easy set-up of the iSprings RCC7AK.
The most common disinfection method involves some form of chlorine or its compounds such as chloramine or chlorine dioxide. Chlorine is a strong oxidant that rapidly kills many harmful micro-organisms. Because chlorine is a toxic gas, there is a danger of a release associated with its use. This problem is avoided by the use of sodium hypochlorite, which is a relatively inexpensive solution used in household bleach that releases free chlorine when dissolved in water. Chlorine solutions can be generated on site by electrolyzing common salt solutions. A solid form, calcium hypochlorite, releases chlorine on contact with water. Handling the solid, however, requires more routine human contact through opening bags and pouring than the use of gas cylinders or bleach, which are more easily automated. The generation of liquid sodium hypochlorite is inexpensive and also safer than the use of gas or solid chlorine. Chlorine levels up to 4 milligrams per liter (4 parts per million) are considered safe in drinking water.[12]

Membrane pore sizes can vary from 0.1 to 5,000 nm depending on filter type. Particle filtration removes particles of 1 µm or larger. Microfiltration removes particles of 50 nm or larger. Ultrafiltration removes particles of roughly 3 nm or larger. Nanofiltration removes particles of 1 nm or larger. Reverse osmosis is in the final category of membrane filtration, hyperfiltration, and removes particles larger than 0.1 nm.[11]
Ultraviolet light (UV) is very effective at inactivating cysts, in low turbidity water. UV light's disinfection effectiveness decreases as turbidity increases, a result of the absorption, scattering, and shadowing caused by the suspended solids. The main disadvantage to the use of UV radiation is that, like ozone treatment, it leaves no residual disinfectant in the water; therefore, it is sometimes necessary to add a residual disinfectant after the primary disinfection process. This is often done through the addition of chloramines, discussed above as a primary disinfectant. When used in this manner, chloramines provide an effective residual disinfectant with very few of the negative effects of chlorination.
The water from this unit is pretty much tasteless to me, which is ideal since tap water tastes awful. I grew up with Culligan, which has a certain taste to me, versus this which is just pure. Haven't tested it but plan to. We also added a line to the fridge ice maker so our ice is purified. It was easy to install in our home, and we've used it three months with no issues. The cables are long. today when our sink clogged and we had to drain it, got a mess over all the filters, and they water tubes were all long enough to put the whole unit (still assembled and attached), into the sink to rinse it off. I'm glad it's made in the USA so I know all the parts have stringent manufacturing guidelines. The only thing I would change, is ordering directly from apec instead ... full review
×