The tourist season got off to a grisly start this year in Gulf Shores, Ala. During a two-day period in early June, four men drowned after being caught in rip currents. The unusually strong currents were invisible, not even roiling the surface. Rip currents occur when water rushing back from the shoreline is channeled through a narrow gap between two sand bars, accelerating the outward flow.

Depending upon the desired product, either the solvent or solute stream of reverse osmosis will be waste. For food concentration applications, the concentrated solute stream is the product and the solvent stream is waste. For water treatment applications, the solvent stream is purified water and the solute stream is concentrated waste.[28] The solvent waste stream from food processing may be used as reclaimed water, but there may be fewer options for disposal of a concentrated waste solute stream. Ships may use marine dumping and coastal desalination plants typically use marine outfalls. Landlocked reverse osmosis plants may require evaporation ponds or injection wells to avoid polluting groundwater or surface runoff.[29]

A properly packed backpack is requisite to your comfort and safety. Incorrect weight distribution leads to muscle aches and unnecessary strain on your spine. Place heavy items – water, food, and cooking gear – in the middle of your pack, close to your body. Use medium weight items – clothing, tarps, and rain gear – to cushion the heavier items, securing them, so the weight does not shift while you are hiking. Pack your sleeping bag in the bottom of your backpack or tie to the bottom. Store items that you are likely to need more frequently in the side and outer pockets – compass and map, sunglasses, toilet tissue and trowel, sunscreen, bug repellent, pocketknife, flashlight, snacks, and a small towel.
It’s extremely important to confirm your water has been purified or treated before drinking. If your water is contaminated and you don’t have bottled water, there are various water purification methods that are used today, and each method has its merits and demerits. Filtering is good for basic water tasks such as sediment and chlorine removal, but in the long run reverse osmosis is the best option. At Schultz Soft Water we focus on reverse osmosis units because they require a lot less energy and time required to make water versus distillation.

Pretreatment is important when working with reverse osmosis and nanofiltration membranes due to the nature of their spiral-wound design. The material is engineered in such a fashion as to allow only one-way flow through the system. As such, the spiral-wound design does not allow for backpulsing with water or air agitation to scour its surface and remove solids. Since accumulated material cannot be removed from the membrane surface systems, they are highly susceptible to fouling (loss of production capacity). Therefore, pretreatment is a necessity for any reverse osmosis or nanofiltration system. Pretreatment in sea water reverse osmosis systems has four major components:

Granular Activated Carbon adsorption: a form of activated carbon with a high surface area, adsorbs many compounds including many toxic compounds. Water passing through activated carbon is commonly used in municipal regions with organic contamination, taste or odors. Many household water filters and fish tanks use activated carbon filters to further purify the water. Household filters for drinking water sometimes contain silver as metallic silver nanoparticle. If water is held in the carbon block for longer periods, microorganisms can grow inside which results in fouling and contamination. Silver nanoparticles are excellent anti-bacterial material and they can decompose toxic halo-organic compounds such as pesticides into non-toxic organic products.[24] Filtered water must be used soon after it is filtered, as the low amount of remaining microbes may proliferate over time. In general, these home filters remove over 90% of the chlorine available to a glass of treated water. These filters must be periodically replaced otherwise the bacterial content of the water may actually increase due to the growth of bacteria within the filter unit.[13]
The clarified water is then fed through a high-pressure piston pump into a series of vessels where it is subject to reverse osmosis. The product water is free of 90.00–99.98% of the raw water's total dissolved solids and by military standards, should have no more than 1000–1500 parts per million by measure of electrical conductivity. It is then disinfected with chlorine and stored for later use.[citation needed]
Ozone disinfection, or ozonation, Ozone is an unstable molecule which readily gives up one atom of oxygen providing a powerful oxidizing agent which is toxic to most waterborne organisms. It is a very strong, broad spectrum disinfectant that is widely used in Europe and in a few municipalities in the United States and Canada. It is an effective method to inactivate harmful protozoa that form cysts. It also works well against almost all other pathogens. Ozone is made by passing oxygen through ultraviolet light or a "cold" electrical discharge. To use ozone as a disinfectant, it must be created on-site and added to the water by bubble contact. Some of the advantages of ozone include the production of fewer dangerous by-products and the absence of taste and odour problems (in comparison to chlorination). No residual ozone is left in the water.[13] In the absence of a residual disinfectant in the water, chlorine or chloramine may be added throughout a distribution system to remove any potential pathogens in the distribution piping.
We were looking for to replace an RO unit that was many years old and were impressed with iSpring's RO / UV / Ph / multi-filter options, with the More-Is-Better paradigm. Patience is required for the multipart installation because the directions are vague. We also had to run a GFCI receptacle for the UV. The UV does warm the water a bit but we remedied this by running an additional line to the fridge for cold water and ice. The system was flushed a half dozen time over two days. The initial glass was cloudy but that cleared to show some carbon from that particular filter. The water taste great and we highly recommend this drinking water system.

These survival tips can help you avoid becoming just another statistic. Accidents are the leading cause of death among U.S. men 18 to 50 years old, accounting for 37,000 of the roughly 148,000 annual fatalities. Some instances of unintentional death, to use the official term, are unavoidable—wrong place, wrong time—but most aren't. Staying alive requires recognizing danger, feeling fear, and reacting. "We interpret external cues through our subconscious fear centers very quickly," says Harvard University's David Ropeik, author of How Risky Is It, Really? Trouble is, even smart, sober, experienced men can fail to register signals of an imminent threat. Here we present 20 easy-to-miss risks, and how to avoid or survive them.

Distillation is a water purification method that utilizes heat to collect pure water in the form of vapor. This method is effective by the scientific fact that water has a lower boiling point than other contaminants and disease-causing elements found in water. Water is subjected to a heat source until it attains its boiling point. It is then left at the boiling point until it vaporizes. This vapor is directed into a condenser to cool. Upon cooling, vapor is reversed into liquid water that is clean and safe for drinking. Other substances that have a higher boiling point are left as sediments in the container.


You have successfully negotiated free fall, deployed your canopy, and are about to touch down. Safe? Nope. Inexperienced solo jumpers trying to avoid an obstacle at the last minute, or experienced skydivers looking for a thrill, might sometimes pull a toggle and enter a low-hook turn. "If you make that turn too low, your parachute doesn't have time to level out," says Nancy Koreen of the United States Parachute Association. Instead, with your weight far out from the canopy, you'll swing down like a wrecking ball.
Photo by mr.smashyContingencies in the wilderness abound, so it is important to plan for as many as possible. A compass will help you find your way; even better is a handheld GPS device. Flashlights and glow sticks help you find your way in the dark, and a flare gun will assist others in finding you during an emergency. For setting up camp, Paracord or rope, a tarp, duct tape, and cable ties are indispensable. Also vital is a good multi-tool, folding shovel, and gloves. Include waterproof matches, lighter, and fire starting kit; redundancy is a good thing in this instance. In a small tin, pack fishhooks and line, razor blades, sewing needles and thread, safety pins, nails, a small magnet, and some cash.

Direct contact membrane distillation (DCMD). Applicable to desalination. Heated seawater is passed along the surface of a hydrophobic polymer membrane. Evaporated water passes from the hot side through pores in the membrane into a stream of cold pure water on the other side. The difference in vapour pressure between the hot and cold side helps to push water molecules through.
Upland lakes and reservoirs: Typically located in the headwaters of river systems, upland reservoirs are usually sited above any human habitation and may be surrounded by a protective zone to restrict the opportunities for contamination. Bacteria and pathogen levels are usually low, but some bacteria, protozoa or algae will be present. Where uplands are forested or peaty, humic acids can colour the water. Many upland sources have low pH which require adjustment.
The reverse osmosis membrane of this system is equipped to process 75 gallons of water per day. Like other popular iSpring reverse osmosis systems, the RCC7AK-UV can easily be mounted under the sink. For the greatest peace of mind when drinking well water, take advantage of the purification power of reverse osmosis combined with the sterilization of UV light in this water filtration system.
To clean the filter, water is passed quickly upward through the filter, opposite the normal direction (called backflushing or backwashing) to remove embedded or unwanted particles. Prior to this step, compressed air may be blown up through the bottom of the filter to break up the compacted filter media to aid the backwashing process; this is known as air scouring. This contaminated water can be disposed of, along with the sludge from the sedimentation basin, or it can be recycled by mixing with the raw water entering the plant although this is often considered poor practice since it re-introduces an elevated concentration of bacteria into the raw water.
In 1904, Allen Hazen showed that the efficiency of a sedimentation process was a function of the particle settling velocity, the flow through the tank and the surface area of tank. Sedimentation tanks are typically designed within a range of overflow rates of 0.5 to 1.0 gallons per minute per square foot (or 1.25 to 2.5 litres per square meter per hour). In general, sedimentation basin efficiency is not a function of detention time or depth of the basin. Although, basin depth must be sufficient so that water currents do not disturb the sludge and settled particle interactions are promoted. As particle concentrations in the settled water increase near the sludge surface on the bottom of the tank, settling velocities can increase due to collisions and agglomeration of particles. Typical detention times for sedimentation vary from 1.5 to 4 hours and basin depths vary from 10 to 15 feet (3 to 4.5 meters).[6]:9.39–9.40[7]:790–1[8]:140–2, 171
×