Pressure exchanger: using the pressurized concentrate flow, in direct contact or via a piston, to pressurize part of the membrane feed flow to near concentrate flow pressure. A boost pump then raises this pressure by typically 3 bar / 50 psi to the membrane feed pressure. This reduces flow needed from the high-pressure pump by an amount equal to the concentrate flow, typically 60%, and thereby its energy input. These are widely used on larger low-energy systems. They are capable of 3 kWh/m3 or less energy consumption.

The ultraviolet rays of the sun can be extremely destructive to microorganisms. We as humans avoid it as much as possible as it can cause skin cancer and other diseases. But we have learned to harness its power and use it to our advantage, especially in decontaminating our water from harmful bacteria and pathogens. UV light has been a standard in the disinfection of water supplies at the municipal level for decades but has recently become available for home use.
Assuming you can get a fire going, and have a metal container. After filtering as many of the particulates as possible. Fill your container with water, place over the fire, bring to a rapid boil, then allow to cool (drinking hot water can induce vomiting). Boiling will kill the harmful bacteria in the water, as they cannot withstand the temperature.
In Situ Chemical Oxidation, a form of advanced oxidation processes and advanced oxidation technology, is an environmental remediation technique used for soil and/or groundwater remediation to reduce the concentrations of targeted environmental contaminants to acceptable levels. ISCO is accomplished by injecting or otherwise introducing strong chemical oxidizers directly into the contaminated medium (soil or groundwater) to destroy chemical contaminants in place. It can be used to remediate a variety of organic compounds, including some that are resistant to natural degradation

A subcategory of sedimentation is the removal of particulates by entrapment in a layer of suspended floc as the water is forced upward. The major advantage of floc blanket clarifiers is that they occupy a smaller footprint than conventional sedimentation. Disadvantages are that particle removal efficiency can be highly variable depending on changes in influent water quality and influent water flow rate.[7]:835–6
Simply fill the provided container with water. Shake the container. Allow the filled container to stand for about an hour. This allows time for the water to become saturated with iodine. Add the iodine to your water container, adding the indicated amount of capfuls (it's about 1 capful to 1 quart). Shake the water container to ensure a proper mixture. Allow the container to sit 20-30 minutes. Afterwards the water is ready to drink.
Bioremediation is a technique that uses microorganisms in order to remove or extract certain waste products from a contaminated area. Since 1991 bioremediation has been a suggested tactic to remove impurities from water such as alkanes, perchlorates, and metals.[26] The treatment of ground and surface water, through bioremediation, with respect to perchlorate and chloride compounds, has seen success as perchlorate compounds are highly soluble making it difficult to remove.[27] Such success by use of Dechloromonas agitata strain CKB include field studies conducted in Maryland and the Southwest region of the United States.[27][28][29] Although a bioremediation technique may be successful, implementation is not feasible as there is still much to be studied regarding rates and after effects of microbial activity as well as producing a large scale implementation method.
Only a part of the saline feed water pumped into the membrane assembly passes through the membrane with the salt removed. The remaining "concentrate" flow passes along the saline side of the membrane to flush away the concentrated salt solution. The percentage of desalinated water produced versus the saline water feed flow is known as the "recovery ratio". This varies with the salinity of the feed water and the system design parameters: typically 20% for small seawater systems, 40% – 50% for larger seawater systems, and 80% – 85% for brackish water. The concentrate flow is at typically only 3 bar / 50 psi less than the feed pressure, and thus still carries much of the high-pressure pump input energy.

Granular Activated Carbon adsorption: a form of activated carbon with a high surface area, adsorbs many compounds including many toxic compounds. Water passing through activated carbon is commonly used in municipal regions with organic contamination, taste or odors. Many household water filters and fish tanks use activated carbon filters to further purify the water. Household filters for drinking water sometimes contain silver as metallic silver nanoparticle. If water is held in the carbon block for longer periods, microorganisms can grow inside which results in fouling and contamination. Silver nanoparticles are excellent anti-bacterial material and they can decompose toxic halo-organic compounds such as pesticides into non-toxic organic products.[24] Filtered water must be used soon after it is filtered, as the low amount of remaining microbes may proliferate over time. In general, these home filters remove over 90% of the chlorine available to a glass of treated water. These filters must be periodically replaced otherwise the bacterial content of the water may actually increase due to the growth of bacteria within the filter unit.[13]


Gas hydrate crystals centrifuge method. If carbon dioxide or other low molecular weight gas is mixed with contaminated water at high pressure and low temperature, gas hydrate crystals will form exothermically. Separation of the crystalline hydrate may be performed by centrifuge or sedimentation and decanting. Water can be released from the hydrate crystals by heating[25]
To clean the filter, water is passed quickly upward through the filter, opposite the normal direction (called backflushing or backwashing) to remove embedded or unwanted particles. Prior to this step, compressed air may be blown up through the bottom of the filter to break up the compacted filter media to aid the backwashing process; this is known as air scouring. This contaminated water can be disposed of, along with the sludge from the sedimentation basin, or it can be recycled by mixing with the raw water entering the plant although this is often considered poor practice since it re-introduces an elevated concentration of bacteria into the raw water.
Filter out pathogens with pine trees. Certain plants are effective at removing pathogens from water, and pine trees are among the best. To remove viruses and bacteria from your water, remove a small branch from a pine tree. Strip the bark from the stick and place the bare stick into a bucket. Slowly pour the water, letting it trickle onto the stick and into the bucket.[10]
To improve the effectiveness and the efficiency, Home Master TMAFC-ERP comes with the permeate pump. Permeate pump increases the pressure of the feed water. Consequently, it reduces the water wastage up to 80% and increases water production by up to 50%. All the systems in our list are wasted 2-3 gallons to produce a single gallon on average. While the water efficiency ratio of this system is 1:1, it means the Home Master TMAFC-ERP wastes only a single gallon. That’s why this under sink RO system marks the first spot in our recommended list of best reverse osmosis systems 2020.
×