Compared to reverse osmosis, filtration is considered effective when it comes to selective elimination of much smaller molecular compounds such as chlorine and pesticides. The other factor that makes filtration less costly is that it does not require a lot of energy needed in distillation and reverse osmosis. It is an economic method of water purification because little water is lost during purification.
The first continuous use of chlorine in the United States for disinfection took place in 1908 at Boonton Reservoir (on the Rockaway River), which served as the supply for Jersey City, New Jersey.[46] Chlorination was achieved by controlled additions of dilute solutions of chloride of lime (calcium hypochlorite) at doses of 0.2 to 0.35 ppm. The treatment process was conceived by Dr. John L. Leal and the chlorination plant was designed by George Warren Fuller.[47] Over the next few years, chlorine disinfection using chloride of lime were rapidly installed in drinking water systems around the world.[48]

In a paper published in 1894, Moritz Traube formally proposed the addition of chloride of lime (calcium hypochlorite) to water to render it "germ-free." Two other investigators confirmed Traube's findings and published their papers in 1895.[42] Early attempts at implementing water chlorination at a water treatment plant were made in 1893 in Hamburg, Germany and in 1897 the city of Maidstone, England was the first to have its entire water supply treated with chlorine.[43]

Sip on pure, clean water with the addition of the APEC Ultimate 6-Stage Reverse Osmosis Water Filter System for home. This reverse osmosis system is easy to mount under the sink and earns top marks for easy installation and excellent customer service. With super capacity filters, you only need to change the filters once a year to enjoy clean and safe water every day.
Bioremediation is a technique that uses microorganisms in order to remove or extract certain waste products from a contaminated area. Since 1991 bioremediation has been a suggested tactic to remove impurities from water such as alkanes, perchlorates, and metals.[26] The treatment of ground and surface water, through bioremediation, with respect to perchlorate and chloride compounds, has seen success as perchlorate compounds are highly soluble making it difficult to remove.[27] Such success by use of Dechloromonas agitata strain CKB include field studies conducted in Maryland and the Southwest region of the United States.[27][28][29] Although a bioremediation technique may be successful, implementation is not feasible as there is still much to be studied regarding rates and after effects of microbial activity as well as producing a large scale implementation method.
If the right equipment is available distillation is another way to ensure removal of bacteria and viruses. This is one method that will allow us to use salt water for drinking. Note: If you own a boat and use it for off shore trips a desalinator such as the Katadyn Survivor series would be a prudent purchase. The Katadyn Survivor 40E can be operated manually or using 12/24 V DC power. We will cover makeshift ways of distillation in future articles.
Sea-water reverse-osmosis (SWRO) desalination, a membrane process, has been commercially used since the early 1970s. Its first practical use was demonstrated by Sidney Loeb from University of California at Los Angeles in Coalinga, California, and Srinivasa Sourirajan of National Research Council, Canada. Because no heating or phase changes are needed, energy requirements are low, around 3 kWh/m3, in comparison to other processes of desalination, but are still much higher than those required for other forms of water supply, including reverse osmosis treatment of wastewater, at 0.1 to 1 kWh/m3. Up to 50% of the seawater input can be recovered as fresh water, though lower recoveries may reduce membrane fouling and energy consumption.
America's national pastime may seem a gentle pursuit, but it is not without its fatal hazards. The 2008 book Death at the Ballpark: A Comprehensive Study of Game-Related Fatalities, 1862–2007 catalogs deaths that have occurred while people were playing, watching, or officiating at baseball games. Among the causes is commotio cordis, a concussion of the heart that leads to ventrical fibrillation when the chest is struck during a critical 10- to 30-millisecond moment between heartbeats. About 50 percent of all victims are athletes (and the vast majority of these are male) engaging in sports that also include ice hockey and lacrosse, the U.S. National Commotio Cordis Registry reports.
Reverse osmosis (RO) is a water purification process that uses a partially permeable membrane to remove ions, unwanted molecules and larger particles from drinking water. In reverse osmosis, an applied pressure is used to overcome osmotic pressure, a colligative property that is driven by chemical potential differences of the solvent, a thermodynamic parameter. Reverse osmosis can remove many types of dissolved and suspended chemical species as well as biological ones (principally bacteria) from water, and is used in both industrial processes and the production of potable water. The result is that the solute is retained on the pressurized side of the membrane and the pure solvent is allowed to pass to the other side. To be "selective", this membrane should not allow large molecules or ions through the pores (holes), but should allow smaller components of the solution (such as solvent molecules, i.e., water, H2O) to pass freely.[1]
The first part of the purification tag team must eliminate microorganisms, like harmful bacteria and parasites. There are a handful of tried and true methods for doing this. The most familiar is boiling. Simply bringing water up to its boiling point of 212 degrees Fahrenheit will kill almost all microorganisms, so just a few minutes of boiling will do the job.
These tablets essentially use chlorination as their method of purification. Sodium chlorite generate chlorine dioxide giving it the ability to treat water. Chlorination, as most know, is a common method of disinfecting water, and is commonly used by municipalities world-wide for this purpose. Chlorine destroys bacteria by destroying the cell walls of the bacterium/virus, killing the organism. Fortunately, when we drink chlorinated water, our digestive system quickly neutralizes the chlorine. So chlorine concentrations along the gastrointestinal tract are, in all likelihood, too low to cause damage. The tablets are wrapped in a metallic foil which makes it easy to store and there are no concerns of a glass bottle breaking. This is one of our favorite items to carry as a backup to our water filtration system.
Inclined flat plates or tubes can be added to traditional sedimentation basins to improve particle removal performance. Inclined plates and tubes drastically increase the surface area available for particles to be removed in concert with Hazen's original theory. The amount of ground surface area occupied by a sedimentation basin with inclined plates or tubes can be far smaller than a conventional sedimentation basin.
Some water supplies may also contain disinfections by-products, inorganic chemicals, organic chemicals, and radionuclides. Specialized methods for controlling formation or removing them can also be part of water treatment. To learn more about the different treatments for drinking water, see the National Drinking Water Clearinghouse’s Fact Sheet Series on Drinking Water TreatmentsExternal.
Energy-recovery pump: a reciprocating piston pump having the pressurized concentrate flow applied to one side of each piston to help drive the membrane feed flow from the opposite side. These are the simplest energy recovery devices to apply, combining the high pressure pump and energy recovery in a single self-regulating unit. These are widely used on smaller low-energy systems. They are capable of 3 kWh/m3 or less energy consumption.
Because the the semi-permeable membrane filters particles at the molecular level, reverse osmosis is extremely effective at removing bacteria, viruses, parasite cysts such as Giardia and Cryptosporidium, heavy metals such as lead and mercury, hard water minerals such as calcium and magnesium, and even fluoride and arsenic. It will not, however, remove certain pesticides and solvents small enough to pass through the membrane.

A subcategory of sedimentation is the removal of particulates by entrapment in a layer of suspended floc as the water is forced upward. The major advantage of floc blanket clarifiers is that they occupy a smaller footprint than conventional sedimentation. Disadvantages are that particle removal efficiency can be highly variable depending on changes in influent water quality and influent water flow rate.[7]:835–6


Post-treatment consists of preparing the water for distribution after filtration. Reverse osmosis is an effective barrier to pathogens, but post-treatment provides secondary protection against compromised membranes and downstream problems. Disinfection by means of ultraviolet (UV) lamps (sometimes called germicidal or bactericidal) may be employed to sterilize pathogens which bypassed the reverse-osmosis process. Chlorination or chloramination (chlorine and ammonia) protects against pathogens which may have lodged in the distribution system downstream, such as from new construction, backwash, compromised pipes, etc.[24]

Iodine tastes just like it smells, fortunately, this is a pretty weak solution, so the taste is not overpowering; it is only slightly worse than city water. The advantages of iodine crystals, is that, one container can treat somewhere in the neighborhood of 10,000 gallons. As well as the fact that, it prepares the water relatively fast. The disadvantage is, as mentioned above, that it is harmful in the long term.
Chlorine is a powerful chemical that has been in use for many years to treat water for home consumption. Chlorine is an effective water purification method that kills germs, parasites and other disease-causing organisms found in ground or tap water. Water can be purified using chlorine tablets or liquid chlorine. As an off-the-shelf water purification product, chlorine is cheap and effective. However, caution should be taken when using chlorine liquid or tablets to treat drinking water. For example, people suffering from thyroid problems should talk to a medical practitioner before using this product. When using chlorine tablets, it is important to apply them in heated water, as they dissolve well in water that is at 21 degree Celsius or higher. Chlorine tablets kill all bacteria leaving your water clean and safe.
Energy-recovery pump: a reciprocating piston pump having the pressurized concentrate flow applied to one side of each piston to help drive the membrane feed flow from the opposite side. These are the simplest energy recovery devices to apply, combining the high pressure pump and energy recovery in a single self-regulating unit. These are widely used on smaller low-energy systems. They are capable of 3 kWh/m3 or less energy consumption.
Granular Activated Carbon adsorption: a form of activated carbon with a high surface area, adsorbs many compounds including many toxic compounds. Water passing through activated carbon is commonly used in municipal regions with organic contamination, taste or odors. Many household water filters and fish tanks use activated carbon filters to further purify the water. Household filters for drinking water sometimes contain silver as metallic silver nanoparticle. If water is held in the carbon block for longer periods, microorganisms can grow inside which results in fouling and contamination. Silver nanoparticles are excellent anti-bacterial material and they can decompose toxic halo-organic compounds such as pesticides into non-toxic organic products.[24] Filtered water must be used soon after it is filtered, as the low amount of remaining microbes may proliferate over time. In general, these home filters remove over 90% of the chlorine available to a glass of treated water. These filters must be periodically replaced otherwise the bacterial content of the water may actually increase due to the growth of bacteria within the filter unit.[13]
The practice of water treatment soon became mainstream and common, and the virtues of the system were made starkly apparent after the investigations of the physician John Snow during the 1854 Broad Street cholera outbreak. Snow was sceptical of the then-dominant miasma theory that stated that diseases were caused by noxious "bad airs". Although the germ theory of disease had not yet been developed, Snow's observations led him to discount the prevailing theory. His 1855 essay On the Mode of Communication of Cholera conclusively demonstrated the role of the water supply in spreading the cholera epidemic in Soho,[39][40] with the use of a dot distribution map and statistical proof to illustrate the connection between the quality of the water source and cholera cases. His data convinced the local council to disable the water pump, which promptly ended the outbreak.
As with any other filter type water purification method, careful attention has to be taken to pathogen/virus and chemicals size. During hurricane Katrina a lot of the water was contaminated with petroleum based chemicals from flooded cars. What is removed from the water is dependent on the filter pore size. However, it is difficult to beat the lightweight option that water purification straws and bottles provide for most situations.
This system can purify up to 50 gallons of water per day and has 5 stages of filtration to remove up to 99 percent of TDS. For every gallon of purified water produced, there are 3 gallons of wastewater. This is an average conversion rate and is much better than some water filtration systems that have 4 or 5 gallons of wastewater for every purified gallon produced.
Only a part of the saline feed water pumped into the membrane assembly passes through the membrane with the salt removed. The remaining "concentrate" flow passes along the saline side of the membrane to flush away the concentrated salt solution. The percentage of desalinated water produced versus the saline water feed flow is known as the "recovery ratio". This varies with the salinity of the feed water and the system design parameters: typically 20% for small seawater systems, 40% – 50% for larger seawater systems, and 80% – 85% for brackish water. The concentrate flow is at typically only 3 bar / 50 psi less than the feed pressure, and thus still carries much of the high-pressure pump input energy.
×