In industry, reverse osmosis removes minerals from boiler water at power plants.[15] The water is distilled multiple times. It must be as pure as possible so it does not leave deposits on the machinery or cause corrosion. The deposits inside or outside the boiler tubes may result in under-performance of the boiler, reducing its efficiency and resulting in poor steam production, hence poor power production at the turbine.

The reverse osmosis membrane of this system is equipped to process 75 gallons of water per day. Like other popular iSpring reverse osmosis systems, the RCC7AK-UV can easily be mounted under the sink. For the greatest peace of mind when drinking well water, take advantage of the purification power of reverse osmosis combined with the sterilization of UV light in this water filtration system.

Advantage is that you are not adding any chemicals to your water, which takes out the guess work as far as dosage. The disadvantage, if it can even be called that, is that you have to have a source of heat(fire, stove, etc.) in order to bring the water to the boiling point. Also we have to remember that this does not remove chemical such as petroleum or pesticides which can be harmful as well.
This system can purify up to 50 gallons of water per day and has 5 stages of filtration to remove up to 99 percent of TDS. For every gallon of purified water produced, there are 3 gallons of wastewater. This is an average conversion rate and is much better than some water filtration systems that have 4 or 5 gallons of wastewater for every purified gallon produced.
In 1904, Allen Hazen showed that the efficiency of a sedimentation process was a function of the particle settling velocity, the flow through the tank and the surface area of tank. Sedimentation tanks are typically designed within a range of overflow rates of 0.5 to 1.0 gallons per minute per square foot (or 1.25 to 2.5 litres per square meter per hour). In general, sedimentation basin efficiency is not a function of detention time or depth of the basin. Although, basin depth must be sufficient so that water currents do not disturb the sludge and settled particle interactions are promoted. As particle concentrations in the settled water increase near the sludge surface on the bottom of the tank, settling velocities can increase due to collisions and agglomeration of particles. Typical detention times for sedimentation vary from 1.5 to 4 hours and basin depths vary from 10 to 15 feet (3 to 4.5 meters).[6]:9.39–9.40[7]:790–1[8]:140–2, 171
×