The desalinated water purity is a function of the feed water salinity, membrane selection and recovery ratio. To achieve higher purity a second pass can be added which generally requires re-pumping. Purity expressed as total dissolved solids typically varies from 100 to 400 parts per million (ppm or mg/litre)on a seawater feed. A level of 500 ppm is generally accepted as the upper limit for drinking water, while the US Food and Drug Administration classifies mineral water as water containing at least 250 ppm.
Different RO water filter systems handle a different number of purified gallons in a day. Normally this capacity goes from 50 to 150 Gallons per day and so on. You must identify the amount of water your family needs in a day. For Small families, reverse osmosis with 50 Gallons per day capacity is suggested while for larger families, Whole house Ro system with minimum 75-100 GPD is suggested.
After Hurricane Sandy, many homeowners used portable generators to replace lost power, leaving the machines running overnight and allowing odorless carbon monoxide to waft inside. The gas induces dizziness, headaches, and nausea in people who are awake, but "when people go to sleep with a generator running, there's no chance for them to realize that something's wrong," says Brett Brenner, president of the Electrical Safety Foundation International.
If the right equipment is available distillation is another way to ensure removal of bacteria and viruses. This is one method that will allow us to use salt water for drinking. Note: If you own a boat and use it for off shore trips a desalinator such as the Katadyn Survivor series would be a prudent purchase. The Katadyn Survivor 40E can be operated manually or using 12/24 V DC power. We will cover makeshift ways of distillation in future articles.
In 1904, Allen Hazen showed that the efficiency of a sedimentation process was a function of the particle settling velocity, the flow through the tank and the surface area of tank. Sedimentation tanks are typically designed within a range of overflow rates of 0.5 to 1.0 gallons per minute per square foot (or 1.25 to 2.5 litres per square meter per hour). In general, sedimentation basin efficiency is not a function of detention time or depth of the basin. Although, basin depth must be sufficient so that water currents do not disturb the sludge and settled particle interactions are promoted. As particle concentrations in the settled water increase near the sludge surface on the bottom of the tank, settling velocities can increase due to collisions and agglomeration of particles. Typical detention times for sedimentation vary from 1.5 to 4 hours and basin depths vary from 10 to 15 feet (3 to 4.5 meters).[6]:9.39–9.40[7]:790–1[8]:140–2, 171
×